Sellafield Site - Inspection ID: 52791

Executive summary

Date(s) of inspection:

  • January 2024

Aim of inspection

The CNI attention level for 'safety case adequacy and currency' is Enhanced, the aim of the inspection is to gather evidence on the effectiveness, use, and understanding of SL's new safety case production processes to support a review of the attention level.

Subject(s) of inspection

  • LC14 - Safety documentation - Rating: Green

Key findings, inspector's opinions and reasons for judgement made

I undertook an LC14 inspection of a safety case whilst it was being developed to look at the application and understanding of Sellafield Ltd's revised safety case processes. The safety case sampled was the Floc retrievals safety case.

I found that the safety case team had applied the revised processes in the spirit in which it was intended. The team were knowledgeable of the requirements of the process and had met the requirements and expectations of the processes.

I have made a few observations of areas for improvement, and one area of good practice. There were no new regulatory issues arising from this inspection, but it will provide evidence towards RI-11251. I judged that the inspection rating was green.

Conclusion

In my view it was clear that the safety case team had applied the revised processes in the spirit in which they were intended. The team were knowledgeable of the requirements of the process and had met the requirements and expectations of the processes. I judge that the inspection rating is green.