Companies fined after radioactive uranium powder spill at nuclear site

Two nuclear industry companies have been fined a combined total of £140,000 after safety failings led to a container of radioactive uranium powder being dropped and rupturing open at a nuclear fuel enrichment site. 

 

Urenco ChemPlants Limited and Babcock Critical Services Limited were sentenced today at South Sefton Magistrates Court following a prosecution brought by the Office for Nuclear Regulation (ONR). 

 

The incident happened at the Urenco site in Capenhurst, Cheshire, inside the Tails Management Facility, which is run by Urenco ChemPlants Limited.  

 

Workers at the facility process a by-product of uranium enrichment and pack the resulting powder into large steel containers, each weighing at least 11 tonnes when full, ready for long-term storage. 

 

On 5 February 2024, a forklift truck driver was moving a full container when he mistakenly tilted the forks forward instead of lowering them, causing the container to slide off, hit a metal guard rail and split open, releasing a quantity of uranium powder.  

 

A banksman had been checking underneath the full containers for any radiological contamination before the container was dropped, and was put at significant risk of harm should the container had fallen during that task.

 

At least 3.3kgs of the uranium powder were released and radiological surveys carried out later, revealed widespread, low levels of contamination across the room. 

 

The dispersed triuranium octoxide powder is a hazardous radioactive material and various long-term and serious health effects can potentially arise from inhalation, ingestion or absorption through the eyes. 

Thankfully, nobody was harmed on this occasion. Tests on the two workers closest to the incident showed no internal radiation exposure, and there was no risk to the public or the environment.  

However, ONR's investigation found that this was largely down to good fortune rather than good safety management. 

ONR found that Urenco ChemPlants Limited were responsible for basic safety failings and had exposed their employees to avoidable risk for a number of years.  

The investigation found that the company failed to adequately assess and manage risks, and that safety shortcomings in both the Tails Management Facility and the operation of the forklift truck contributed to the incident. 

Urenco ChemPlants Limited’s working practices required its employees to stand close to forklift trucks. This is a recognised danger in industry, and free guidance on managing the associated risks is widely available.  

The company also did not have dedicated kits to deal with uranium powder spills, so employees had to improvise and gather items themselves including a vacuum cleaner, bags and wipes.  

Babcock Critical Services Limited provides the site's emergency response service, including fire, medical and security teams.

ONR found multiple basic failings on their part, including the company having no radiation risk assessment in place for its work at Capenhurst, having no registration for radiological work, not consulting or appointing a radiation protection adviser, and having no radiation protection supervisors; all of which are legal requirements.  

Emergency responders had inadequate training for an incident at the facility and did not have the right equipment to seal the damaged container.  

Two of Babcock Critical Services Limited’s employees had not been issued with personal radiation monitoring devices, despite being expected to attend incidents involving radiation on site.  

Both companies cooperated with ONR's enquiries and have since made significant improvements in safety procedures following the incident. 

Urenco ChemPlants Limited has removed the need for workers to stand close to forklift trucks - introducing a three-metre exclusion zone and they are no longer required to check underneath full containers for radiological contamination.  

The company has trained operators to use a safety lock device on the forklift truck and has also set up an emergency store for dealing with uranium powder spills.  

Babcock Critical Services Limited has carried out new risk assessments, appointed a radiation protection adviser and radiation protection supervisors, improved training and equipment, and put in place a process to ensure every responder is issued with radiation monitoring devices before each shift. 

Urenco ChemPlants Limited was charged under Section 2 of the Health and Safety at Work etc. Act 1974, for failing to ensure the health and safety of its employees, in relation to the risks arising from the transportation of DV70 containers. 

Babcock Critical Services Limited was charged under Section 2 of the Health and Safety at Work etc. Act 1974, with failing to ensure the health and safety of its employees, in relation to the risks arising whilst undertaking emergency response services at the Capenhurst site. 

Both companies pleaded guilty to these offences at the sentencing hearing today.  

Urenco ChemPlants Limited and Babcock Critical Services Limited were fined £50,000 and £90,000 respectively.

In addition, Urenco ChemPlants Limited and Babcock Critical Services were ordered to pay court costs of £16,304.85 and £15,481.66 respectively.

It should be noted that Urenco UK Ltd, the site licensee, is not a defendant in this case.

As part of the sentencing determination, District Judge James Clarke ruled the health and safety breaches represented a high culpability bracket for Babcock Critical Services Limited and medium culpability bracket for Urenco ChemPlants Limited. 

The category level of harm for both defendants was agreed as Level A, Category 3 (low risk of death), with Urenco ChemPlants Limited classed as a ‘large size organisation’ and Babcock Critical Services Limited classed as a 'medium size organisation' for the purposes of sentencing.

After the sentencing, Tom Eagleton, Head of Safety Regulation, Decommissioning, Fuel and Waste sites at ONR, said:

This incident could have had much more serious consequences.  

"Responsibility for safety lies with those who create and control the hazards, and both companies fell short of the basic standards we expect, from risk assessment to training and equipment.  

"Some of those shortfalls had gone unaddressed for a long time.  

"A key lesson from this case is that dutyholders must give equal consideration to conventional health and safety risks and radiological hazards and ensure their risk assessments remain under review as new operational experience and evidence become available. 

"Where we find serious failings, we will act, and we will prosecute where it is appropriate to do so. Both companies have now made improvements, and it is vital that they, and the wider nuclear industry, learn from what happened.  

"Protecting workers and the public is always our priority, and as an independent regulator we will continue to hold dutyholders to account so that robust standards are maintained." 