Ultra Nuclear Limited (Site) - Inspection ID: IR-53825

Executive summary

Date(s) of inspection: 

June 2025

Aim of inspection

The purpose of this inspection is to seek evidence in support of Ultra Nuclear Limited, Material Balance Area: QPLE's compliance with the Nuclear Safeguards (EU Exit) Regulation 2019 (NSR19). The dutyholder's accountancy arrangements are appropriate and proportionate for the qualifying nuclear facility and that they are implemented adequately for nuclear material accountancy and control of Qualifying Nuclear Material (QNM).

Subject(s) of inspection

  • FSE 3 Competence Management - Rating: GREEN
  • FSE 4 Reporting, Anomalies, and Investigations - Rating: GREEN
  • FSE 6 Measurement Programme and Control - Rating: GREEN
  • FSE 7 Nuclear Material Tracking - Rating: GREEN
  • FSE 9 Material Balance - Rating: GREEN
  • NSR19 Reg06 - Accountancy and control of qualifying nuclear material - Rating: GREEN
  • NSR19 Reg07 - Accountancy and control plan - Rating: GREEN
  • NSR19 Reg31 - Declaration of basic technical characteristics, stock list and accounting records for qualifying nu - Rating: GREEN

Key findings, inspector's opinions and reasons for judgement made

This report presents the findings of the ONR Safeguards Compliance Inspection at Curtis-Wright Wimborne Limited (QPLE).

To draw an independent and informed regulatory judgement, I sampled the dutyholder's BTC and ACP that it contained adequate descriptions of its procedures and its operations for QNM which is proportionate to and appropriate for the qualifying facility in accordance with the Nuclear Safeguards (EU Exit) Regulations 2019 (NSR19), Regulations 7 and 31(5).

Also, as part of this inspection, I sampled evidence of the dutyholder's implementation of its local arrangements and procedures for the accountancy and control of qualifying nuclear materials, including verification of operating and accounting records for nuclear material transfers, followed by a plant walkdown of the facility areas in accordance with Regulation 6 of NSR19.

The inspection was performed in line with relevant ONR guidance, which can be found on ONR’s website Nuclear safeguards | Office for Nuclear Regulation including the ONR Safeguards subdivision operational schedule for 2025/2026 and ONR Safeguards integrated inspection strategy for Qualifying Nuclear Facilities with Limited Operation (QNFLO).

Based on the sample I inspected, I raised a minor observation for the dutyholder to consider documentation of the Phsyical Inventory Listing and Material Balance Report process.

Conclusion

Overall, I judge from the evidence sampled, that the dutyholder's procedures, accountancy and control of QNM are being implemented in a proportionate manner, in line with their own arrangements, appropriately signposted within the ACP and are compliant with Regulations 6, 7 and 31(5) and in line with ONR's Safeguards regulatory expectations (ONMACS).

Upon consideration of the ONR guidance on inspection ratings, I judge that a rating of GREEN (no formal action) is appropriate.