Skip to content

Inutec Ltd. (Winfrith) - Inspection ID: 53584

Executive summary

Date(s) of inspection: December 2024

Aim of inspection

The intention of this ONR inspection was to conduct a Licence Condition (LC) 11 emergency exercise demonstration inspection at the Tradebe Inutec site on the 10 December 2024.

Subject(s) of inspection

  • LC11 - Emergency arrangements - Rating: Green

Key findings, inspector's opinions and reasons for judgement made

I carried out an LC11 inspection at the Tradebe Inutec site of exercise “Cerium Green” on the 10 December 2024. ONR safety inspectors lead the exercise evaluation, as per a normal LC11 demonstration.  The end-of-exercise feedback session to the dutyholder's Exercise Manager provided areas of learning and good practice observed during the exercise.

Conclusion

In my opinion, the Licensee's arrangements for compliance with LC11 are adequate and appropriate for the low off-site risk profile for the site and met the expectations of ONR guidance for LC11. I therefore concluded that this inspection identified no further matters that may impact significantly on nuclear safety and rated it green with no regulatory issues raised