Ian Farmer Associates (1998) Ltd. (Site) Transport - Inspection ID: 52927

Executive summary

Date(s) of inspection: April 2024

Aim of inspection

The purpose of the inspection is to review compliance of the dutyholder's arrangements for class 7 radioactive material, covering consignor and consignee duties. This is a re-inspection, as the previous visit was concluded early.

Subject(s) of inspection

  • Transport (Non-nuclear) Appropriate management system - Rating: Green
  • Transport (Non-nuclear) Contingency plans in accordance with IRR Reg 13 - Rating: Green
  • Transport (Non-nuclear) Dangerous Goods Safety Advisor subsection 1.8.3 ADR - Rating: Green
  • Transport (Non-nuclear) Designation of Controlled or supervised areas Reg 17 IRR17 - Rating: Green
  • Transport (Non-nuclear) Emergency arrangements - Rating: Not rated
  • Transport (Non-nuclear) IRR17 Regulation 19 additional requirements - Rating: Green
  • Transport (Non-nuclear) Local rules Reg 18 IRR17 - Rating: Green
  • Transport (Non-nuclear) Radiation Protection Adviser Reg 14 IRR17 - Rating: Green
  • Transport (Non-nuclear) Radiation Risk Assessment Reg 8 of IRR 17 - Rating: Green
  • Transport (Non-nuclear) Security Plan - Rating: Green
  • Transport (Non-nuclear) Training - Rating: Green
  • Transport (Non-nuclear) Transport documentation - Rating: Green
  • Transport (Non-nuclear) Vehicle Requirements Part 8 - Rating: Green

Key findings, inspector's opinions and reasons for judgement made

The inspector identified numerous examples of the duty holder meeting relevant good practice in reducing risk to levels that are ALARP, including; suitable IRR17 radiation risk assessments for the transport of x2 nuclear density gauges (NDG); HSE consent under IRR17; appropriate local rules and work instructions; transport contingency planning; training and plans for maintaining competence; procedures for the creation of transport plans and dangerous goods notes; arrangements for despatch, carriage, and return of NDG to storage bunker; arrangements for radiation protection programme, and its implementation; management system appropriate to the size of the duty holder.

Conclusion

The inspection findings were presented to IFA at the close of the inspection. There were no identified non-compliances, but the inspector made three observations which IFA committed to address.
 I judged an overall rating of 'Green - no formal action' was appropriate for this inspection as there were no significant shortfalls identified in the delivery of safety.