DHL Global Forwarding (UK) Ltd, compliance inspection Transport of Radioactive Materials

  • Site: Transport Competent Authority
  • IR number: 21-010
  • Date: June 2021
  • LC numbers: N/A

Executive summary

ONR regulates the civil transport of radioactive material by road, rail and inland waterway in Great Britain (GB). The ONR Transport Competent Authority (TCA) is responsible for delivering non-nuclear transport inspection and enforcement activities. This particular inspection forms part of that delivery function with reference to Carriage of Dangerous Goods and Use of Transportable Pressure Equipment Regulations 2009 (CDG), the Ionising Radiations Regulations 2017 (IRR17) and the Radiation (Emergency Preparedness and Public Information) Regulations 2019 (REPPIR19). CDG refers to the European Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) and ONR used ADR 2019 during this inspection (www.unece.org).

Purpose of Intervention

The purpose of the inspection was to review DHL Global Forwarding (UK) Ltd’s arrangements associated with the road transport of radioactive material. ONR carried out this inspection at the Hayes site on 16 June 2021.

Interventions Carried Out by ONR

The chosen inspection sample included:

  • notification, registration, or consent – IRR17 Regulation 5, 6 or 7;
  • a suitable and sufficient radiation risk assessment (RRA) – IRR17 Regulation 8;
  • suitable and sufficient measures to restrict exposure – IRR17 Regulation 9;
  • suitable and sufficient Contingency Planning and/or Emergency Arrangements – IRR17 Regulation 13 and CDG 2009 Regulation 24 & Schedule 2;
  • suitable and sufficient emergency planning in accordance with REPPIR19
  • adequate information, instruction, and training – IRR17 Regulation 15 and ADR 1.3.1;
  • adequate Transport Documentation – ADR 5.4;
  • adequate Security arrangements – ADR 1.10; and
  • a suitable and sufficient Management System – ADR 1.7.3.

Key Findings, Inspector's Opinions and Reasons for Judgements Made

The inspector sampled the arrangements deployed by DHL Global Forwarding (UK) Ltd for the transport of radioactive materials, including the associated arrangements for protecting workers against the effects of ionising radiations and reducing risks as low as reasonably practicable (ALARP). 

The inspector compared relevant statutory requirements with both prescribed arrangements and actual practice. A number of examples of the duty holder meeting relevant good practice in reducing risk to levels that are as low as reasonably practicable were identified, including its radiation protection programme and training. The inspector identified no non-compliances during the inspection.

During the inspection, the inspector also suggested certain improvements to transport practices that would be prudent for DHL Global Forwarding (UK) Ltd to consider.

Conclusion of Intervention

 DHL Global Forwarding (UK) Ltd demonstrated that for aspects of its transport operations it met the requirements of CDG, ADR and IRR17. Based on the inspection sample, the inspector identified no non-compliances with relevant legislation and suggested 5 improvements. The inspector discussed these during the inspection and DHL Global Forwarding (UK) Ltd gave a commitment to address them.

For this intervention, the inspector gave an IIS Rating of GREEN, due to there being evidence that relevant good practice was generally met, with only minor shortfalls identified when compared with appropriate benchmarks, that legal duties were complied with, although there may be minor contraventions of specific administrative requirements, and that no significant shortfalls were identified in the delivery of safety or security functions.