Sizewell C [Site] - Inspection ID: 54145

Executive summary

Date(s) of inspection: 

October 2025

Aim of inspection

The purpose of this inspection was to gain assurance that Sizewell C Ltd (SZC) arrangements for compliance with LC7 (Incidents on the site) and their implementation comply with legal requirements. The purpose of LC7 is to ensure that incidents on the site are notified, recorded, investigated and reported by the licensee. Organisational learning, including learning from incidents on the site, as well as from other relevant external sources make a key contribution to the continual improvement of any effective safety regime.

Subject(s) of inspection

  • CDM 15 - Rating: GREEN
  • Health & Safety at Work Act - Rating: GREEN
  • LC 07 - Incidents on the site - Rating: GREEN

Key findings, inspector's opinions and reasons for judgement made

I led a joint regulatory inspection at Sizewell C Ltd (SZC). The regulatory team comprised an inspector from SZC's independent nuclear assurance function (INA), observation by the Environment Agency, two observers from the National Atomic Energy Agency of Poland and inspectors from the Office for Nuclear Regulation (ONR). This was an inspection to gain assurance that SZC's arrangements for compliance with LC7 (Incidents on the site) and their implementation comply with legal requirements.  

This scope sampled written arrangements SZC have in place to record, investigate, and report incidents on site against relevant good practice which includes Technical Inspection Guide (TIG) number 007 (Incidents on the Site); Construction (Design and Management) Regulations 2015 and the Health and Safety at Work etc Act 1974.  The inspection sampled key roles identified in those arrangements to confirm and understand the role responsibilities of those individuals; gain evidence of SZC’s organisational learning, including learning from incidents on the site, as well as from other relevant external sources and; by discussion with SZC how the trending information is utilised with evidence of how this has led to learning.

This inspection highlighted no significant regulatory issues. 

A small number of minor observations were identified and actions were confirmed, where appropriate.

Overall, on the basis of the inspection and evidence sampled, I judge that arrangements for LC 07 compliance (Incidents on the site) including application of the Health and Safety at Work etc Act 1974 and Construction (Design and Management) Regulations 2015, are being implemented appropriately and are aligned with relevant good practice. 

Conclusion

Following ONR's inspection, I judge that relevant good practice was met and SZC have demonstrated adequate arrangements for the notification, recording, investigation and recording of incidents on the site. There were many areas of good practice and some areas that SZC should consider for improvements. No regulatory issues were raised.