The purpose of this inspection was to undertake a licence condition (LC) compliance inspection and a number of other inspection activities at Dounreay in accordance with the 2018/19 Integrated Intervention Strategy (IIS) for the site to confirm that the licensee is controlling its hazards and complying with its statutory obligations.
The purpose of this inspection was to confirm compliance against the requirements of LC17 [Management systems]: Specifically DSRL’s arrangements for the management of their supply chain and the implementation of those arrangements in support of the following projects:
In addition, the inspection also provided the opportunity to conduct other inspections, specifically:
Not applicable.
The LC17 inspection focused on DSRL’s supply chain management arrangements and the implementation of those arrangements in support of two of two decommissioning projects on site, namely:
This inspection also provided an opportunity to conduct a plant walk-down within DMTR. Acknowledging that the amount of work ongoing was limited, ONR were satisfied that the supervisory and control arrangements for this stage of the work were adequate.
Overall, we consider that DSRL’s arrangements and their implementation in those areas inspected meet the requirements of LC17. In addition, we consider that the site is making adequate progress in addressing matters raised in previous inspections and continues to demonstrate an adequate internal regulation capability. We did not identify any matter impacting on nuclear safety that required any further immediate regulatory action.